Grade | Remanenz Induktion | Koerzitivfeldstärke | Intrinsische Koerzitivfeldstärke | Maximal Energie Produkt | Arbeitstemperatur | Dichte | |||||||||||||||||
Br | HcB | HcJ | (BH)max | Tw | ρ | ||||||||||||||||||
T | KGs | KA/m | KOe | KA/m | KOe | KJ/m³ | MGOe | ℃ | g/cm3 | ||||||||||||||
Allgemeiner Prozess | |||||||||||||||||||||||
N38 | 1.23-1.30 | 12.3-13.0 | ≥876 | ≥11 | ≥955 | ≥12 | 287-318 | 36-40 | ≤80 | ≥7.5 | |||||||||||||
N40 | 1.26-1.32 | 12.6-13.2 | ≥876 | ≥11 | ≥955 | ≥12 | 302-334 | 38-42 | ≤80 | ≥7.5 | |||||||||||||
N42 | 1.29-1.35 | 12.9-13.5 | ≥876 | ≥11 | ≥955 | ≥12 | 318-350 | 40-44 | ≤80 | ≥7.5 | |||||||||||||
N45 | 1.32-1.38 | 13.2-13.8 | ≥876 | ≥11 | ≥955 | ≥12 | 334-366 | 42-46 | ≤80 | ≥7.5 | |||||||||||||
N48 | 1.37-1.43 | 13.7-14.3 | ≥876 | ≥11 | ≥955 | ≥12 | 358-390 | 45-49 | ≤80 | ≥7.5 | |||||||||||||
N50 | 1.40-1.45 | 14.0-14.5 | ≥876 | ≥11 | ≥955 | ≥12 | 374-406 | 47-51 | ≤80 | ≥7.5 | |||||||||||||
N52 | 1.42-1.48 | 14.2-14.8 | ≥836 | ≥10.5 | ≥876 | ≥11 | 390-422 | 49-53 | ≤80 | ≥7.5 | |||||||||||||
N55 | 1.46-1.51 | 14.6-15.1 | ≥860 | ≥10.8 | ≥955 | ≥12 | 406-438 | 51-55 | ≤80 | ≥7.5 | |||||||||||||
N38M | 1.23-1.30 | 12.3-13.0 | ≥915 | ≥11.5 | ≥1114 | ≥14 | 287-318 | 36-40 | ≤100 | ≥7.5 | |||||||||||||
N40M | 1.26-1.32 | 12.6-13.2 | ≥939 | ≥11.8 | ≥1114 | ≥14 | 302-334 | 38-42 | ≤100 | ≥7.5 | |||||||||||||
N42M | 1.29-1.35 | 12.9-13.5 | ≥963 | ≥12.1 | ≥1114 | ≥14 | 318-350 | 40-44 | ≤100 | ≥7.5 | |||||||||||||
N45M | 1.32-1.38 | 13.2-13.8 | ≥987 | ≥12.4 | ≥1114 | ≥14 | 334-366 | 42-46 | ≤100 | ≥7.5 | |||||||||||||
N48M | 1.37-1.43 | 13.7-14.3 | ≥1019 | ≥12.8 | ≥1114 | ≥14 | 358-390 | 45-49 | ≤100 | ≥7.5 | |||||||||||||
N50M | 1.40-1.45 | 14.0-14.5 | ≥1043 | ≥13.1 | ≥1114 | ≥14 | 374-406 | 47-51 | ≤100 | ≥7.5 | |||||||||||||
N52M | 1.42-1.48 | 14.2-14.8 | ≥1059 | ≥13.3 | ≥1114 | ≥14 | 390-422 | 49-53 | ≤100 | ≥7.5 | |||||||||||||
N54M | 1.46-1.51 | 14.6-15.1 | ≥995 | ≥12.5 | ≥1035 | ≥13 | 406-438 | 51-55 | ≤100 | ≥7.5 | |||||||||||||
N35H | 1.17-1.24 | 11.7-12.4 | ≥876 | ≥11.0 | ≥1353 | ≥17 | 263-295 | 33-37 | ≤120 | ≥7.5 | |||||||||||||
N38H | 1.23-1.30 | 12.3-13.0 | ≥915 | ≥11.5 | ≥1353 | ≥17 | 286-318 | 36-40 | ≤120 | ≥7.5 | |||||||||||||
N40H | 1.26-1.32 | 12.6-13.2 | ≥939 | ≥11.8 | ≥1353 | ≥17 | 302-334 | 38-42 | ≤120 | ≥7.5 | |||||||||||||
N42H | 1.29-1.35 | 12.9-13.5 | ≥963 | ≥12.1 | ≥1353 | ≥17 | 318-350 | 40-44 | ≤120 | ≥7.5 | |||||||||||||
N45H | 1.32-1.38 | 13.2-13.8 | ≥987 | ≥12.4 | ≥1353 | ≥17 | 334-366 | 42-46 | ≤120 | ≥7.5 | |||||||||||||
N48H | 1.37-1.43 | 13.7-14.3 | ≥1011 | ≥12.7 | ≥1353 | ≥17 | 358-390 | 45-49 | ≤120 | ≥7.5 | |||||||||||||
N50H | 1.40-1.45 | 14.0-14.5 | ≥1027 | ≥12.9 | ≥1353 | ≥17 | 374-406 | 47-51 | ≤120 | ≥7.5 | |||||||||||||
N52H | 1.42-1.48 | 14.2-14.8 | ≥1059 | ≥13.3 | ≥1353 | ≥17 | 390-422 | 49-53 | ≤120 | ≥7.5 | |||||||||||||
N33SH | 1.14-1.21 | 11.4-12.1 | ≥852 | ≥10.7 | ≥1592 | ≥20 | 247-279 | 31-35 | ≤150 | ≥7.5 | |||||||||||||
N35SH | 1.17-1.24 | 11.7-12.4 | ≥876 | ≥11.0 | ≥1592 | ≥20 | 263-295 | 33-37 | ≤150 | ≥7.5 | |||||||||||||
N38SH | 1.23-1.29 | 12.3-12.9 | ≥915 | ≥11.5 | ≥1592 | ≥20 | 287-318 | 36-40 | ≤150 | ≥7.5 | |||||||||||||
N40SH | 1.26-1.32 | 12.6-13.2 | ≥939 | ≥11.8 | ≥1592 | ≥20 | 302-334 | 38-42 | ≤150 | ≥7.5 | |||||||||||||
N42SH | 1.29-1.35 | 12.9-13.5 | ≥963 | ≥12.1 | ≥1592 | ≥20 | 318-350 | 40-44 | ≤150 | ≥7.5 | |||||||||||||
N45SH | 1.32-1.38 | 13.2-13.8 | ≥987 | ≥12.4 | ≥1592 | ≥20 | 334-366 | 42-46 | ≤150 | ≥7.5 | |||||||||||||
Fortsetzung folgt |
Grade |
Remanenz Induktion |
Koerzitivfeldstärke |
Intrinsische Koerzitivfeldstärke |
Maximal Energie Produkt |
Arbeitstemperatur |
Dichte |
|||||||||||||||||||
Br |
HcB |
HcJ |
(BH)max |
Tw |
ρ |
||||||||||||||||||||
Grade |
T |
KGs |
KA/m |
KOe |
KA/m |
KOe |
KJ/m³ |
MGOe |
℃ |
g/cm3 | |||||||||||||||
N48SH | 1.37-1.43 | 13.7-14.3 | ≥1011 | ≥12.7 | ≥1592 | ≥20 | 358-390 | 45-49 | ≤150 | ≥7.5 | |||||||||||||||
N50SH | 1.40-1.45 | 14.0-14.5 | ≥1027 | ≥12.9 | ≥1592 | ≥20 | 374-406 | 47-51 | ≤150 | ≥7.5 | |||||||||||||||
N52SH | 1.42-1.48 | 14.2-14.8 | ≥1035 | ≥13 | ≥1512 | ≥19 | 390-422 | 49-53 | ≤150 | ≥7.5 | |||||||||||||||
N30UH | 1.08-1.13 | 10.8-11.3 | ≥796 | ≥10.0 | ≥1990 | ≥25 | 223-255 | 28-31 | ≤180 | ≥7.5 | |||||||||||||||
N33UH | 1.14-1.18 | 11.4-11.8 | ≥852 | ≥10.5 | ≥1990 | ≥25 | 247-279 | 31-35 | ≤180 | ≥7.5 | |||||||||||||||
N35UH | 1.17-1.24 | 11.7-12.4 | ≥876 | ≥11.0 | ≥1990 | ≥25 | 263-295 | 33-37 | ≤180 | ≥7.5 | |||||||||||||||
N38UH | 1.23-1.29 | 12.3-12.9 | ≥915 | ≥11.5 | ≥1990 | ≥25 | 287-318 | 36-40 | ≤180 | ≥7.5 | |||||||||||||||
N40UH | 1.26-1.32 | 12.6-13.2 | ≥939 | ≥11.8 | ≥1990 | ≥25 | 302-334 | 38-42 | ≤180 | ≥7.5 | |||||||||||||||
N42UH | 1.28-1.35 | 12.8-13.5 | ≥963 | ≥12.1 | ≥1990 | ≥25 | 310-350 | 39-44 | ≤180 | ≥7.5 | |||||||||||||||
N45UH | 1.32-1.38 | 13.2-13.8 | ≥987 | ≥12.4 | ≥1990 | ≥25 | 334-366 | 42-46 | ≤180 | ≥7.5 | |||||||||||||||
N48UH | 1.37-1.42 | 13.7-14.2 | ≥1019 | ≥12.8 | ≥1910 | ≥24 | 358-390 | 45-49 | ≤180 | ≥7.5 | |||||||||||||||
N30EH | 1.08-1.15 | 10.8-11.5 | ≥812 | ≥10.2 | ≥2388 | ≥30 | 223-255 | 28-32 | ≤200 | ≥7.5 | |||||||||||||||
N33EH | 1.14-1.21 | 11.4-12.1 | ≥851 | ≥10.7 | ≥2388 | ≥30 | 247-279 | 31-35 | ≤200 | ≥7.5 | |||||||||||||||
N35EH | 1.17-1.24 | 11.7-12.4 | ≥876 | ≥11.0 | ≥2388 | ≥30 | 263-295 | 33-37 | ≤200 | ≥7.5 | |||||||||||||||
N38EH | 1.23-1.29 | 12.3-12.9 | ≥915 | ≥11.5 | ≥2388 | ≥30 | 287-318 | 36-40 | ≤200 | ≥7.5 | |||||||||||||||
N40EH | 1.26-1.32 | 12.6-13.2 | ≥939 | ≥11.8 | ≥2388 | ≥30 | 302-334 | 38-42 | ≤200 | ≥7.5 | |||||||||||||||
N42EH | 1.28-1.35 | 12.8-13.5 | ≥963 | ≥12.1 | ≥2388 | ≥30 | 310-350 | 39-44 | ≤200 | ≥7.5 | |||||||||||||||
N45EH | 1.33-1.38 | 13.3-13.8 | ≥995 | ≥12.5 | ≥2308 | ≥29 | 334-366 | 42-46 | ≤200 | ≥7.5 | |||||||||||||||
N28AH | 1.04-1.12 | 10.4-11.2 | ≥772 | ≥9.7 | ≥2786 | ≥35 | 207-239 | 26-30 | ≤230 | ≥7.5 | |||||||||||||||
N30AH | 1.08-1.15 | 10.8-11.5 | ≥812 | ≥10.2 | ≥2786 | ≥35 | 223-255 | 28-32 | ≤230 | ≥7.5 | |||||||||||||||
N33AH | 1.14-1.21 | 11.4-12.1 | ≥852 | ≥10.7 | ≥2786 | ≥35 | 247-279 | 31-35 | ≤230 | ≥7.5 | |||||||||||||||
N35AH | 1.17-1.24 | 11.7-12.4 | ≥876 | ≥11.0 | ≥2786 | ≥35 | 263-295 | 33-37 | ≤230 | ≥7.5 | |||||||||||||||
N38AH | 1.23-1.27 | 12.3-12.7 | ≥923 | ≥11.6 | ≥2786 | ≥35 | 287-318 | 36-40 | ≤230 | ≥7.5 | |||||||||||||||
N40AH | 1.26-1.31 | 12.6-13.1 | ≥939 | ≥11.8 | ≥2628 | ≥33 | 302-334 | 38-42 | ≤230 | ≥7.5 | |||||||||||||||
N42AH | 1.29-1.35 | 12.9-13.5 | ≥955 | ≥12.0 | ≥2628 | ≥33 | 318-350 | 40-44 | ≤230 | ≥7.5 | |||||||||||||||
Fortsetzung folgt |
Grade | Remanenz Induktion | Koerzitivfeldstärke | Intrinsische Koerzitivfeldstärke | Maximal Energie Produkt | Arbeitstemperatur | Dichte | |||||||||||||||||
Br | HcB | HcJ | (BH)max | Tw | ρ | ||||||||||||||||||
T | KGs | KA/m | KOe | KA/m | KOe | KJ/m³ | MGOe | ℃ | g/cm3 | ||||||||||||||
Diffusionsprozess | |||||||||||||||||||||||
G48SH | 1.37-1.42 | 13.7-14.2 | ≥1011 | ≥13 | ≥1592 | ≥20 | 358-390 | 45-49 | ≤150 | ≥7.5 | |||||||||||||
G50SH | 1.40-1.45 | 14.0-14.5 | ≥1027 | ≥13.2 | ≥1592 | ≥20 | 374-406 | 47-51 | ≤150 | ≥7.5 | |||||||||||||
G52SH | 1.42-1.48 | 14.2-14.8 | ≥1067 | ≥13.4 | ≥1592 | ≥20 | 390-422 | 49-53 | ≤150 | ≥7.5 | |||||||||||||
G55SH | 1.46-1.51 | 14.6-15.1 | ≥1083 | ≥13.6 | ≥1592 | ≥20 | 406-438 | 51-55 | ≤150 | ≥7.5 | |||||||||||||
G45UH | 1.33-1.38 | 13.3-13.8 | ≥978 | ≥12.4 | ≥1990 | ≥25 | 334-366 | 42-46 | ≤180 | ≥7.5 | |||||||||||||
G48UH | 1.37-1.42 | 13.7-14.2 | ≥1027 | ≥12.9 | ≥1990 | ≥25 | 358-390 | 45-49 | ≤180 | ≥7.5 | |||||||||||||
G50UH | 1.40-1.45 | 14.0-14.5 | ≥1051 | ≥13.2 | ≥1990 | ≥25 | 374-406 | 47-51 | ≤180 | ≥7.5 | |||||||||||||
G52UH | 1.42-1.48 | 14.2-14.8 | ≥1067 | ≥13.4 | ≥1990 | ≥25 | 390-422 | 49-53 | ≤180 | ≥7.5 | |||||||||||||
G54UH | 1.46-1.51 | 14.6-15.1 | ≥1075 | ≥13.5 | ≥1990 | ≥25 | 406-438 | 51-55 | ≤180 | ≥7.5 | |||||||||||||
G40EH | 1.26-1.31 | 12.6-13.1 | ≥955 | ≥12.0 | ≥2388 | ≥30 | 302-334 | 38-42 | ≤200 | ≥7.5 | |||||||||||||
G44EH | 1.29-1.35 | 12.9-13.5 | ≥971 | ≥12.2 | ≥2388 | ≥30 | 318-350 | 40-44 | ≤200 | ≥7.5 | |||||||||||||
G46EH | 1.33-1.38 | 13.3-13.8 | ≥1011 | ≥12.7 | ≥2388 | ≥30 | 334-366 | 42-46 | ≤200 | ≥7.5 | |||||||||||||
G48EH | 1.37-1.42 | 13.7-14.2 | ≥1027 | ≥12.9 | ≥2388 | ≥30 | 358-390 | 45-49 | ≤200 | ≥7.5 | |||||||||||||
G50EH | 1.40-1.45 | 14.0-14.5 | ≥1051 | ≥13.2 | ≥2308 | ≥29 | 374-406 | 47-51 | ≤200 | ≥7.5 |
Rectangular Bar of Silver-based Alloy Permanent Magnet
Features:
Material composition: Using advanced silver-based alloy materials, combined with permanent magnet manufacturing technology, to ensure that the product has excellent magnetic properties and stability.
Shape and size: The product is rectangular in design, and the length, width and thickness can be customized according to customer needs.
Magnetic properties: It has the characteristics of high remanence, high coercivity and low hysteresis loop, ensuring its magnetic stability in various environments.
Stability: good corrosion resistance and oxidation resistance, can be used in a variety of environments for a long time without affecting its magnetic properties.
Wide range of applications: suitable for various equipment or systems that require strong magnetic field environments.
Product application scope:
Motors and generators: Used to manufacture high-performance motors and generators to improve energy conversion efficiency.
Sensors and instruments: As the core components of magnetic field sensors or instruments, they are used to measure, detect and control magnetic field intensity.
Medical equipment: such as magnetic resonance imaging (MRI) equipment, magnetic therapy equipment, etc., providing a stable and uniform magnetic field environment.
Aerospace: used to manufacture navigation equipment, attitude control systems, etc. to ensure precise navigation and stable control of aircraft.
Scientific research and teaching: As magnetic experimental equipment for laboratory teaching and scientific research, it helps students and scientific researchers have an in-depth understanding of the principles and applications of magnetism.
Precautions:
Do not expose the product to extreme temperatures or humidity as this may affect its magnetic properties and stability.
Do not bring the product into close contact with sources of strong magnetic fields to avoid magnetic field interference or damage to the product.
When handling the product, wear protective gloves and glasses to avoid eye damage from scratches or splashes.
If you need consultation and feedback, please contact us, we will contact you as soon as possible!
As well known Rectangular bar of pure silver permanent magnets Suppliers and Rectangular bar of pure silver permanent magnets exporter in China, ST Magnet Co., Ltd provides a solid guarantee and foundation for the excellent quality of the NdFeB magnets.
Customized industrial permanent magnets are magnets tailored to specific applica...
Rectangular pure silver permanent magnets, as the name implies, are rectangular-...
Features of high-purity neodymium magnetsNeodymium magnets are a powerful perman...
Permanent magnet rings (Ring Strong Pure Permanent Magnet Ring Magnet) are mater...
Ring Strong Pure Permanent Magnets are a key component in various industries and...
Hole Pure Permanent Magnet is a magnetic material with unique physical propertie...